ACTUATORS
1
ACT-79
For further information www.norgren.com
QM/8000/61 Guide Block
For RM/8000/M and RM/28000/M
ø 12 to ø 25mm
Maximum load
In the case of shock load applications, the figures given in the diagrams above must be reduced by a factor of 2.
Maximum load capacity is dependent on the outstroke of a horizont ally installed
guide unit. In the case of short stroke operation, the load capacity figures taken
from the diagram must be multiplied by the correction factor (diagram 2).
In the load capacity graph (diagram 1), the short stroke corrections have already
been taken into account for anoutstroke > 60 mm
Maximum load capacity depending on outstroke
(diagram 1) (diagram 2)
Deflection caused by
own weight
(diagram 3)
Deflection caused by
a load of 10 N
(diagram 4)
100
80
60
40
20
0
0 100 200 300 400 500 600
8020-8025
Reduction of load capacity for short stroke operation
1,0
0,9
0,8
0,7
0,6
0,5
0 20 40 60
0 100 200 300 400 500 600
f
2,5
2,0
1,5
1,0
0,5
0
8020-8025
0 100 200 300 400 500 600
f
2,5
2,0
1,5
1,0
0,5
0
8020-8025
The total deflection of guide rods will be determined by the addition of that due to
own weight (diagram 3) and that due to load capacity (diagram 4).
Load capicity (N)
Outstroke (mm)
Stroke (mm)
Outstroke (mm) Outstroke (mm)
Correction factor Deflection (mm) Deflection (mm)
G-QA-8032-Hub-61-1 (GB)
2
1
f
G-QA-8032-Hub-61-2 (GB)
1
2
1
Centre of gravity
2
Outstroke